gb
fr
de
ibs ibs ibs ibs ibs

ECL101 wide bandwidth measuring system

ECL101 inductive measuring system (eddy-current)

High bandwidth performance

Where precision measurement is required for high speed applications, the ECL101 delivers linear output at up to an exceptional bandwidth of 80kHz.  Typical examples of high speed applications include measurement of motion or thermal growth of high speed spindles; observation of high speed vibrations or ultrasonic applications. ihe system can be calibrated in the field.

 

Key Specifications

  • Resolution down to 30 nm (@ 1 kHz)
  • 1kHz, 10kHz or 80 kHz bandwidth (factory set)
  • Range 0,5mm to 15mm
  • Linearity 0,25% (non-ferrous)  0.50% (ferrous)

 

Output features

  • Adjustable offset
  • Analogue outputs ( 0-10 VDC)
  • In-field calibration possible
  • Single channel 

 

Probe choices

Probe model numbers include diamater in mm. The target size must be at least 3 times the probe diameter to maintain specifications. See our probes page for more details. The resolution depends on the selected probe, range and bandwidth. Please contact us for expert advice

Probe model

Range (mm)**

Min. target size (mm)

Material type

Resolution (nm)

@ 1kHz

 

@ 10 kHz

 

@ 80 kHz

U3 0,05 - 0,55 6 Non-ferrous 30 60 200
      Ferrous 40 80 300
U5 0,25 - 1,50 10,2 Non-ferrous 60 100 250
      Ferrous 90 150 400
U8 0,35 - 2,35 18,6 Non-ferrous 100 160 400
      Ferrous 130 210 500
U12 0,60 - 4,10 30 Non-ferrous 200 280 700
      Ferrous 260 350 1200
U18 0,75 - 5,75 37,4 Non-ferrous 240 480 3200
      Ferrous 320 640 4500
U25 1,25 - 9,25 75 Non-ferrous 350 700 5300
      Ferrous 350 700 5300
U38 1,50 - 14,0 114 Non-ferrous 550 1100 8300
      Ferrous 550 1100 8300
U50 2,0 - 17,0 150 Non-ferrous 660 1300 10000
      Ferrous 660 1300 10000

** near gap - far gap

 

Click here for more eddy-current position measuring solutions.